IOS Impulse Oscillometry
Tidal breathing analysis with Impulse Oscillometry (IOS) has demonstrated to be informative and differentiated in the early detection and follow up of pulmonary diseases like asthma, COPD and idiopathic pulmonary fibrosis. IOS is almost independent of patient cooperation and can test a larger patient range than spirometry alone, from children to adult to geriatric patients.
IOS is available as a stand-alone device combined with a spirometry measurement program (MasterScreen IOS and Vyntus IOS) or as an add-on module to the MasterScreen series.
The oscillations of the multi- frequency measurement signal penetrate the respiration tract at varying depths. Whereas 20 Hz signals are absorbed (shunted) in the large airways, 5 Hz oscillations penetrate the entire lung. Thus, the respiratory resistance Rrs of the large airways can be differentiated from the lung reactance Xrs of the small airways.
* based on the Bio Burden DIN EN ISO 11737-1: Report 18AA0088 1. Z L Borrill, C M Houghton, A A Woodcock, J Vestbo, and D Singh Medicines Evaluation Unit, North-west Lung Centre, Wythenshawe Hospital, Manchester, UK Br J Clin Pharmacol. 2005 April; 59(4): 379–384. doi: 10.1111/j.1365-2125.2004.02261.x. 2. Yaegashi M, Yalamanchili V, Kaza V, Weedon J, Heurich A, Akerman M. Respir Med. 2007 May;101(5):995-1000. 3. Mansur AH, Manney S, Ayres JG. Resp Med. 2007 Sep 25. Respiratory Medicine, Birmingham Heartlands Hospital NHS Trust, Birmingham, West Midlands, UK. 4. Marotta A, Klinnert, M, Price, M, Larsen, G. Liu, A.H. J Allergy Clin Immunol 2003; 112(2): 317-322. Division of Pediatric Allergy and Immunology, National Jewish Medical and Research Center, and the Department of Pediatrics, University of Colorado Health Sciences Center, Denver, 80206, USA. 5. Skloot G, Goldman M, Fischler D, Goldman C, Schechter C, Levin S, Teirstein A. Chest. 2004 Apr;125(4):1248-55. Division of Pulmonary and Critical Care Medicine, Mount Sinai School of Medicine, New York, NY, USA.
Service is essential to keep medical equipment operational and safe. Our Nordic service team consists of experienced service technicians stationed across the Nordic countries. Our service technicians are ready to take on your every service need.”

For accurate and safe bronchial challenge testing
Vyntus APS is an Aerosol Provocation System. Up-to-date and sophisticated electronics and mechanics allow for optimal use of its nebulization technology with precise dosing. For the observation measurements Vyntus APS combines with the Vyntus PNEUMO and/ or the Vyntus IOS in one system.
APS nebulizer system integrates into Vyaire MasterScreen™ and Vyntus™ instruments – Spirometry, IOS Impulse Oscillometry, Rocc and BODY Plethysmography. The nebulizer system is powered by SentrySuite™ software and is able to test a broad age range: from 4 years to adult. Choose between single and multiple concentration testing.

For all essential spirometry testing
The modular JAEGER Vyntus™ PNEUMO belongs to the Vyntus Family and is combinable with Vyntus APS for bronchial challenge testing and/or Vyntus IOS Impulse Oscillometry for measuring central and peripheral airway resistance.
Use your Vyntus Pneumo for all of the essential spirometry testing: Flow/Volume-loop (FVC), Slow Vital Capacity (SVC), Maximum Voluntary Ventilation (MVV), Pre and Post medication testing or therapy control.
Optionally, Vyntus Pneumo allows expanding your diagnostic possibilities with measurements like Rocc, P0.1, Pmax, SNIP, rhinomanometry and compliance. Vyntus Pneumo is enhanced by the workflow- and quality-driven SentrySuite™ Software.
The reliable, proven, accurate, heated Jaeger pneumotach has been selected as the measurement device of choice in hundreds of publications. Its excellent dynamic range allows for testing a broad population, from small children to athletes. Thousands of PFT labs profit daily from its high performance.

Untethered six-minute walk test
Vyntus™ WALK allows patients to perform an untethered six-minute walk test (6MWT) by wearing wireless sensors that communicate data to a technician-held tablet PC. Standardize testing to the recommended is 6MWT protocol, because consistent testing yields consistent data for comparison
The system is both patient- and technician-friendly and because we know a single sensor does not fit all clinical needs, comes with an array of easy-to-wear sensors. Because standardizing the complete testing process is critical to meaningful data for patient trending, Vyaire has integrated the complete ATS testing standards in the workflow-driven tablet software application.

The Katana sport is a modern and reliable treadmill that can be connected to external ECG- and pulmonary devices as well as to a Lode software network (LEM or LCRM). The Lode Katana sport offers smooth acceleration and is continuously adjustable in a range of 0,5 – 30 km/h. The walking surface of 190 x 70 cm and elevation of 0 – 25%, make this treadmill the perfect solution for use in sport medical settings. The treadmill is equipped with a 7″ Control Unit with Touchscreen and fixed side handrails. The treadmill is executed with a special Lode Slat Technology with 106 soft grip covered slats that allows for high speed and a natural walking and running treadmill experience. Its Unique bearing technology delivers high speeds at low noise levels while needing low maintenance.